Viessmann Boiler Fault Codes Explained

A white wall-hung boiler with its small digital display panel and the pipework and valves coming out underneath

A Viessmann Vitodens shows a fault as a two-character code next to a fault symbol. Codes starting with F mostly mean the burner has locked out: F2 is an overheat trip and F4 means no flame was detected. Number codes such as 10 or 30 usually point at a sensor. Find your code below.

How do I read a Viessmann fault code?

Look at the code as well as the fault symbol. On the Vitodens 100-W WB1B every fault flashes, and the code tells you the type: F codes such as F2 and F4 lock the burner out until it is reset, while sensor faults clear themselves once the cause is fixed, so pressing reset does nothing. Newer touch-display models show R next to the flashing symbol when the burner is locked out.

The codes fall into rough groups. Two-digit numbers such as 10, 18, 30 and 38 are sensor faults, a short circuit or a broken lead on the outside, boiler water or return sensor. Codes starting with F, such as F2, F4 and F9, mean the burner control unit is in a fault state. A9 and similar codes are communication faults with a connected thermostat or control.

Viessmann builds several generations of Vitodens, and its own online fault checker lists some codes against specific models only. The table in your boiler’s manual is the final word for your model.

Which Viessmann codes come up most often?

These are the lockouts householders most often search for, with what Viessmann’s own documentation says about each.

  • F2, temperature limiter has responded: the boiler overheated. Viessmann’s checks start with the system water level, the circulation pump and venting air from the system.
  • F4, no flame signal: the boiler tried to light and did not see a flame. The manual lists the ignition and ionisation electrode, gas pressure, the gas valve, the ignition module and the condensate drain.
  • F1: maximum flue gas temperature exceeded on the Vitodens 100-W WB1B, with the same water and pump checks as F2.
  • F9 and FA: fan faults, either the fan speed is too low at start-up or the fan has not stopped when it should.

Only a pressure top-up and a single reset are householder jobs. Everything else in the list involves testing inside the casing. If you smell gas, ventilate, shut the meter valve if you can reach it safely, leave switches alone, and call 0800 111 999 from outside before anything else.

What can I safely try on a Viessmann?

Check the pressure gauge. Low water is behind many overheat trips, and if it is low our boiler pressure repair page covers what to do. Check other gas appliances work and a prepayment meter has credit. In freezing weather, look at the condensate pipe outside, because Viessmann lists the condensate drain as an F4 cause.

Then reset once, only for an F code, or when R shows next to the flashing fault symbol on newer models. On older Vitodens models with rotary selectors you turn the selector briefly to the reset position and back. On other models, follow the reset step in your user manual. If the same code returns, stop.

Getting a Viessmann repaired

Gas work is carried out by Gas Safe registered engineers. The engineer reads the fault history, tests the part the code points to and tells you what they find. The visit starts with the £60 call-out and the repair price is agreed with you on site before any work starts. Book through boiler repairs, or emergency boiler repair if you have no heat or hot water tonight.

Common Viessmann fault codes
CodeWhat it meansCan you clear it yourself?
F1Maximum flue gas temperature exceededYes, once; call if it returns
F2Temperature limiter has responded: the boiler overheatedYes, once; call if it returns
F3Flame signal already present when the burner startsYes, once; call if it returns
F4No flame signal detected, so the burner locked outYes, once; call if it returns
F8Gas valve closes too lateYes, once; call if it returns
F9Fan speed too low when the burner startsYes, once; call if it returns
FAFan has not stopped when it shouldYes, once; call if it returns
0CMains voltage too lowNo, call an engineer
10Outside temperature sensor short circuitNo, call an engineer
18Outside temperature sensor lead brokenNo, call an engineer
30Boiler water temperature sensor short circuitNo, call an engineer
38Boiler water temperature sensor lead brokenNo, call an engineer
A9Communication fault with a connected OpenTherm controlNo, call an engineer

Viessmann codes explained

Questions people ask

Why won’t my Viessmann reset?

If the symbol is not flashing and no R appears, the burner is not locked out, so a reset has no effect; note the code and report it to an engineer. If it is flashing and the code returns at once, the cause is still there and needs an engineer.

Are Viessmann fault codes the same on every model?

No. The common lockout codes such as F2 and F4 carry the same meaning across many Vitodens models, but lists vary by generation, so check the manual for your model.