Boiler fault codes
Potterton Boiler Fault Codes Explained

Potterton Promax boilers show an E followed by a number. Two-digit codes show as E then the number, and three-digit ones are split, so E133 flashes as E1 then 33. Note both halves, then check the list below: low pressure and a few lockouts you can deal with, the rest need an engineer.
The Promax code table
Potterton boilers are made by Baxi Heating, and the Promax range uses the same display logic as Baxi’s Duo-tec. The user guide lists these codes. If you are seeing a bare E1 on a Potterton, it is the first half of one of the three-digit codes.
- E20: heating temperature sensor fault.
- E28: flue sensor fault, which can also mean a blocked flue or condensate drain.
- E50: hot water temperature sensor fault.
- E110: safety thermostat has tripped on overheat.
- E119: water pressure below 0.5 bar.
- E125: no circulation in the heating circuit.
- E130: flue sensor has tripped on overheat.
- E133: gas supply interrupted or no flame detected.
- E160: fan or fan wiring fault.
What you can do and what you cannot
For E119, top the system up with the blue-handled filling loop under the boiler to 1 to 1.5 bar; the boiler restarts on its own. The same low-pressure causes and checks apply as on a Baxi showing E119. For E110, E130 and E133, turn the selector to reset and hold it for at least five seconds, once. E20, E28, E50, E125 and E160 are listed by Potterton as faulty components, so a reset will not help, although in a frost it is worth thawing the condensate pipe before you assume E28 is a sensor.
Other Potterton models, older and newer, use different displays and code lists. If what you see does not match the table, go by the user guide that came with your boiler.
If you smell gas, do not reset anything. Open windows, turn off the gas at the meter if it is safe to reach, use no switches, and call the National Gas Emergency Service on 0800 111 999 from outside.
Getting a Potterton fixed
If a code keeps coming back, or names a part, book an emergency boiler repair. The visit starts with the £60 call-out at any hour, and the repair price is agreed with you on site before any work starts. Gas work is carried out by Gas Safe registered engineers. For lockouts that keep returning, our explainer on boiler ignition lockout covers the usual causes.
| Code | What it means | Can you clear it yourself? |
|---|---|---|
| E20 | Central heating temperature sensor fault | No, call an engineer |
| E28 | Flue sensor fault, blocked flue or frozen condensate pipe | No, call an engineer |
| E50 | Hot water temperature sensor fault | No, call an engineer |
| E110 | Overheat: the safety thermostat has tripped | Yes, once; call if it returns |
| E119 | Water pressure below about 0.5 bar | Yes, once; call if it returns |
| E125 | Water is not circulating round the heating circuit | No, call an engineer |
| E130 | Flue overheat: the flue sensor has tripped | Yes, once; call if it returns |
| E133 | Gas supply interrupted or no flame detected | Yes, once; call if it returns |
| E160 | Fan or fan wiring fault | No, call an engineer |
| E168 | Control board lockout | No, call an engineer |
Potterton codes explained
Questions people ask
Where is the reset on a Potterton Promax?
The selector switch on the front panel has a reset position. Turn it fully to reset and hold for at least five seconds, then release.
Why does my Potterton keep showing E119?
The system keeps losing water. Common causes are a leaking pressure relief valve, a flat expansion vessel or a slow leak on the pipework. If you top up more than occasionally, have it checked.